Thermo King Apu Owners Manual

Posted on by  admin

Thermo King - electronic parts. Enlarge enlarge. Our company provides for sale original spare part catalogs, workshop manuals, diagnostic software for all models.

  • Thermo King Service Directory for the location and. Operating Instructions Thermo King TriPace. Ignite if they come in contact with TriPac electrical.
  • View and Download Thermo King TriPac operator's manual online. Auxiliary Heating/Cooling Temperature Management System. TriPac Air Conditioner pdf manual download.

APU's I've had were supplemented with oil fired Bunk Heaters such as Webastos, Espar etc. For example, on a Webastos unit, it may have a separate control which looks like a dial. The truck has to be off and not running in order for it to work. Lift up your bottom bunk and have a look. If you have a square looking box with ducting tubes coming out of it, that's part of the APU A/C unit.

Look beside it. If there's another box, usually rectangular in shape, and a vent coming directly out of it and located on the under side of your bunk, that would be your bunk heater. You can also check the bunk area for separate heater controls.

The images below may or may not be what you have, but no harm in checking. The one on the left is for an Espar bunk heater and the one on the right (The Dial) is the control unit for a Webastos bunk heater.

Could be a digital control for newer units. It may be located just below the bunk as well. See if you have something similar and more help could be provided whether you have this or not. Just need to know more info. Don't get impatient with the heat knob.

It takes a good 5-10 minutes for the unit to warm up and the fan to kick on before you hear something. The same with the shutdown, the unit will blow until it cools down then it will shut off.

You can go outside and look at the little heater exhaust pipe and it will puff smoke in the warm up stage. Then you know it's working. Thermo King Tripacs have the ability to add aftermarket heaters like Espar and Webasto are the big ones.

Most are hooked up independently but might share duct work or the blower. It's up to the installer what route he wants to go as you have a few choices. Lift the bunk up and you'll see all the guts. Each one has their own website with how to use the different controls or how to find the trouble codes.

. Operator’s Manual TriPac™ Auxiliary Heating/Cooling Temperature Management System TK 53035-19-OP (Rev. 6, 12/11). TriPac Auxiliary Heating/Cooling Temperature Management System TK 53035-19-OP (Rev. 6, 12/11) Copyright© 2005 Thermo King Corp., Minneapolis, MN, USA Printed in USA. Thermo King dealer. The procedures described herein should only be undertaken by suitably qualified personnel.

Failure to implement these procedures correctly may cause damage to the Thermo King unit or other property or personal injury. First Aid—Refrigerant Oil.9 TriPac Unit).21 Safety Decals. Standby Truck Integration.33 TriPac Warranty.55 Truck Integration Selector Switch. Table of Contents Recover Refrigerant.64 CALIFORNIA Proposition 65 Warning. Table of Contents. Introduction There is nothing complicated about operating and maintaining IMPORTANT: This manual is published for informational your Thermo King unit, but a few minutes studying this purposes only and the information furnished herein should manual will be time well spent.

Introduction. Thermo King dealer. However, there are several general safety lacerations. Service work on the evaporator or practices you should be aware of: condenser coils is best left to a certified Thermo King technician. DANGER: Always turn the TriPac Main Power. Safety Precautions Refrigerant Oil Refrigerant Observe the following precautions when working with or Although fluorocarbon refrigerants are classified as safe, around refrigerant oil: observe caution when working with refrigerants or around areas where they are being used in the servicing of your unit.

WARNING: Always wear goggles or safety glasses to protect eyes from refrigerant oil contact. Safety Precautions First Aid First Aid—Refrigerant Oil Eyes: Immediately flush eyes with large amounts of water for First Aid—Refrigerant at least 15 minutes while holding the eyelids open. Get prompt medical attention. Eyes: For contact with liquid, immediately flush eyes with Skin: Remove contaminated clothing. Safety Precautions Safety Decals AMA690 AMA647 Figure 3: Shut Off Before Fueling Warning Figure 1: Caution - Unit May Start Automatically AMA646 Figure 2: Belt and Pulley Warning. The TriPac is started to heat the coolant as required.

By using TriPac, drivers can reduce fuel cost, rest comfortably during stops and comply with local, state and federal anti-idle laws. 7.5 hp 2 cylinder diesel engine - EPA Tier II TriPac System. Thermo King TM-15-XD compressor for air conditioning The TriPac system includes several major components:. Diesel fuel-fired sleeper compartment air heater. An APU (auxiliary power unit).

Figure 6: Condenser Figure 5: TriPac APU Condenser Auxiliary Power Unit The TriPac Air Conditioning Condenser is mounted on the The TriPac APU contains the diesel engine, air conditioning back of the truck cab. Compressor, alternator and engine power switch. (Evaporator installed under sleeper cab bunk) Heater Evaporator The TriPac Heater is typically installed in the cargo The TriPac air conditioning Evaporator is typically installed compartment under the truck cab sleeper compartment. It under the bunk in the truck cab sleeper compartment.

Air ducts draws fuel from the truck’s diesel fuel tank and electric power. Compressor The TriPac air conditioning compressor is mounted in the TriPac APU and is driven by the TriPac engine. Refrigeration lines connect the compressor to the TriPac air conditioning condenser on the back wall of the truck cab and the evaporator, usually mounted under the truck sleeper compartment bunk.

King

9/06, it is part of the binary pressure closes to allow compressor operation. Switch, mounted on the receiver-drier, typically near the TriPac condenser. On models manufactured during 9/06 and after, a High Pressure Cutout Switch (HPCO) is located at the receiver/drier. The CLC option is designed for warm climate operation and switch opens the engine will shut down and an “Eng” Alarm also to isolate the TriPac system from the tractor engine Code will be displayed on the HMI. Typical causes for an open coolant if desired.

Unit Description Fuses Fuse Number Amp Rating Component Protected / Circuit Starter / 8S Glowplugs / H HMI Controller / — Cab Heater / RED Standby Switch / 2A Standby Integration / IGN Fuel Solenoid / 8DP Engine Switch / 8FET Engine Start Signal / 7X/7A. Unit Description Fuse Number Amp Rating Component Protected / Circuit Fuse Number Amp Rating Component Protected / Circuit Pre-cooler Fan / PCF Condenser Fan / 7CF Evaporator Fan / PWM1/PWM2/7D Compressor Clutch / 7CL Heater On / 26/YLW Voltage Sense / SEN Main Power / 2 Ground / CH Hourmeter (Option) / 2. CAUTION: Use fuel suitable for the climate you operate in (see truck engine manufacturer’s recommendations). Blending used engine oil with diesel fuel is not permitted in the TriPac system. It will plug the filters and will not allow the air heater to run properly.

Thermo King reserves the right to void all warranty on the unit. Coolant should be visible in coolant tank sight glass.

Belts: Make sure the TriPac APU belts are in good condition and adjusted to the proper tension. For more information about belt tension, see the Specifications chapter. Manual Pretrip Inspection (Before Starting the TriPac Unit). TriPac HMI Controller Description and Operation The TriPac is operated using an HMI (Human Machine Interface) Controller which is typically mounted on a wall in the truck cab sleeper compartment.

The HMI Controller includes a display screen, operation keys and indicator LEDs. Up and Down Arrow Keys The HMI Controller Main Power Key is The HMI Controller Up and Down Keys used to turn the TriPac system on and off are used to raise and lower the temperature from the sleeper compartment. The green setpoint in the display.

ON to provide sleeper compartment air conditioning, air circulation, truck battery voltage sensing and engine coolant temperature sensing. This key also allows access to the diesel engine hourmeter reading.

The APU does not have to be On to operate the TriPac sleeper compartment heater. TriPac HMI Controller Description and Operation Operating Modes Fan Mode The fans can be turned on for air circulation in the truck cab. Air Conditioning Mode Fan speed is selected and battery voltage sensing is enabled. The APU must be enabled. Figure 13: Engine On/Off Switch The Engine On/Off Switch is located inside the TriPac APU housing on the right side of the frame. This switch must be in the On position for the TriPac engine to operate.

Apu

TriPac HMI Controller Description and Operation TriPac HMI Controller Operation Enable APU System The Engine On/Off Switch (inside the TriPac APU) must Press HMI Controller Main Power Key be on for the engine to run. Press the HMI Controller APU Key to enable the diesel power unit and also enable sleeper Press the Main Power Key. TriPac HMI Controller Description and Operation Engine Hourmeter Display Select Mode of Operation When the APU Key is initially pressed, the TriPac unit Press the HMI Mode Key to select the desired operating engine hourmeter reading will be displayed. The display mode.

Thermo King Apu User Manual

The HMI setpoint temperature minimum is 50 degrees and the maximum is 90 degrees. The TriPac heater will operate while the Fans are off (no fan LED is illuminated – fan is in “Null”). If additional air. with the Arctic option) the TriPac will shut down. The TriPac will restart if the TriPac system is on and any of these conditions require a restart. (The truck’s ignition switch must be in the Off or Accessory position.) No alarm codes will.

To Clear Alarm Codes TriPac HMI Controller alarm codes are: Record the alarm code shown in the display. To clear an alarm code, use the HMI Main Power Key to turn off the TriPac Eng:. This code indicates that the that the “8” circuit has a system.

Standby Truck Integration system to be controlled by an external source which is typically the truck’s ignition system. This is used to disable the TriPac When the truck’s ignition switch is in the Off or Accessory system when the truck’s engine is running. The display will position, the TriPac APU will operate normally if the APU show “Sby”. TriPac HMI Controller Description and Operation. Typically, when the inverter detects an AC load, it supply. Dangerous arcing may result. Automatically turns on and converts dc to ac to power onboard 120 volt ac devices.

If the TriPac is enabled and the inverter. Optional Power Inverter draws truck battery voltage down below the voltage limit established for the installation, the TriPac will start and attempt to recharge the truck batteries back to the level specified. If the TriPac is not enabled, the inverter could drain the truck batteries below the level required to start the truck or the TriPac. 1 Diesel fuel is acceptable cold weather fuel operate in (see truck engine manufacturer’s recommendations). Blending used engine oil with diesel fuel is not permitted in the TriPac system. It will plug the filters and will not allow the air heater to run properly.

Thermo King reserves the right to void all warranty on the unit. Specifications Oil Type. API Type CI-4 or better multigrade oil API Synthetic Type CI-4 or better after first 1000 hours (optional) API Type CJ-4 or better multigrade oil is required for units equipped with the optional DPF (Diesel Particulate Filter) Oil Viscosity Multigrade Oil Ambient Temperature.

Specifications Coolant System Capacity (TriPac engine only) 0.6 quarts (0.6 liters) 2.75 quarts (2.6 liters) with Closed Loop Cooling Engine Coolant Type: Conventional Conventional coolant (antifreeze) is green or blue-green. Units equipped with conventional coolant do not have an ELC nameplate on the expansion tank. Specifications 10 psig (69 kPa) Radiator Cap Pressure, Closed Loop Cooling Drive Belts to compressor, 12 V alternator, water pump Compressor Compressor TM-15-XD Compressor Oil Charge 8 oz. (236.5 ml).

Compressor Oil Type (R134a Oil Viscosity Refrigerant Used) Polyalkylene glycol (PAG 100) TK P/N 203-502 R-134a Refrigeration System Refrigerant Charge 1.2 lbs. Specifications Fuses Component Protected / Circuit Voltage Starter/8S Glowplugs/H HMI Controller / — Cab Heater/RED Standby Switch/2A Standby Integration/IGN Fuel Solenoid/8DP Engine Switch/8FET Engine Start Signal/7X/7A Pre-cooler Fan/PCF Condenser Fan/7CF Evaporator Fan / PWM1/PWM2/7D Compressor Clutch / 7CL. Specifications Heater On / 26/YLW Voltage Sense / SEN Main Power / 2 Ground / CH Hourmeter (Option) / 2 Hourmeter (Option) / 8D Hourmeter (Option) / 26 Supplemental Heater Contactor (Extreme Arctic Option) / SHR Supplemental Heater (Extreme Arctic Option) / SH Oil Pan Heater (Extreme Arctic Option) / OPH. Specifications Fusable Link, 12 Gauge, APU Main (Prior To Power 9/06) Belt Tension Field Reset Engine/Compressor/Alternator Belt The belt tension should be set at 95 lbs force.

Thermo

A deflection of 1/4” between the alternator and compressor (longest free span of belt) may be used if a guage is not available to test tension. Specifications Truck Sleeper Compartment Heater (D2) Heat Output (±10%) 7,500 BTU/hr Boost (2.2 kW) 6,150 BTU/hr High (1.8 kW) 4,100 BTU/hr Medium (1.2 kW) 2,900 BTU/hr Low (0.85 kW) Current at 12v (±10%) 8.3 amps - Start 2.8 amps - Boost 1.9 amps - High 1.0 amps - Medium 0.7 amps - Low. Specifications Motor Speed 800 ± 140 RPM - Boost 4000 ± 120 RPM - High 2800 ± 80 RPM - Medium 2000 ± 60 RPM - Low 600 ± 20 RPM - Adjustment in circulation mode with temperature sensor, internal. 0 RPM - Adjustment in fresh air mode with temperature sensor, external. Specifications Truck Sleeper Compartment Heater (D4 - Option) Heat Output (±10%) 13,600 BTU/hr Boost (4.0 kW) 10,200 BTU/hr High (3.0 kW) 6,800 BTU/hr Medium (2.0 kW) 3,400 BTU/hr Low (1.0 kW) Current at 12v (±10%) 8.3 amps - Start 3.3 amps - Boost 2.0 amps - High 1.1 amps - Medium 0.6 amps - Low. Specifications Motor Speed 4400 ± 130 RPM - Boost 3600 ± 100 RPM - High 2800 ± 80 RPM - Medium 1600 ± 50 RPM - Low 600 ± 20 RPM - Adjustment in circulation mode with temperature sensor, internal.

0 RPM - Adjustment in fresh air mode with temperature sensor, external. Specifications Optional Power Inverter 1800 Watts; see manufacturer’s specifications Optional Extreme Arctic Package Components Approximate Approximate Current Draw Resistance— (Amps) at 12.5 (Ohms) Coolant Heater (800 Watts) 0.25 Oil Pan Heater (300 Watts) 0.65 Supplemental Heater Contactor Coil 13.5 NOTE: Disconnect components from unit circuit to check resistance. Inspect air cleaner.

Change as needed, or annually. Inspect fuel pre-filter. Change as required or annually. Change fuel filter.

Thermo King brand fuel filter is required. Drain water from fuel tank and check vent.

1,000 1,000 Hour Interval - Oil change interval is every 1,000 hours of Hour operation only when using a Thermo King brand oil filter and CI-4 or Intervals better oil. Units with optional DPF require CJ-4 or better oil. Maintenance Inspection Schedule Pre-Trip 500 Hrs Annual Inspect/Service These Items 2,000 Hrs ELECTRICAL. Check operation of protection shutdown circuits. Check alternator voltage.

Thermo King Apu Troubleshooting

Check alternator bearings. See Note 1. Inspect battery terminals. Inspect electrical connections. Maintenance Inspection Schedule Pre-Trip 500 Hrs Annual Inspect/Service These Items 2,000 Hrs STRUCTURAL. Visually inspect unit for fluid leaks (coolant, oil, refrigerant). Visually inspect unit for damaged, loose or broken parts.

Inspect, clean and (if necessary) replace evaporator air filter. It may be necessary to check or replace it more often if conditions require it.

Maintenance Inspection Schedule Pre-Trip 500 Hrs Annual Inspect/Service These Items 2,000 Hrs A/C SYSTEM. Check refrigerant level.

Check refrigerant lines for rubbing or damage. HEATER.

Start and run for at least 20 minutes each month. Maintenance Inspection Schedule. TriPac Warranty Terms of the Thermo King Warranty are available on request. Please reference document TK 50046 for the Thermo King TriPac Warranty.

TriPac Warranty. (APU cover must be removed to view the nameplate).

Engine: Nameplate located on the top of the engine. The engine is mounted in the TriPac APU housing. Compressor: Nameplate located on compressor body. The engine driven compressor is located in the TriPac APU housing. Serial Number Locations. TriPac Glossary This glossary is published for informational purposes only and CFC: Chlorofluorocarbon.

A chlorine-based refrigerant the information being furnished herein should not be consisting of chlorine, fluorine and carbon. Example: R12. In considered as all-inclusive or meant to cover all contingencies. HCFC refrigerants are not normally due to moisture in the refrigerant and the formation used in modern Thermo King units. Of ice at the expansion valve. The expansion valve may be Hertz: A unit of frequency equal to one cycle per second.

LPCO (Low Pressure Cut Out Switch): A receiver tank: A refrigerant storage device included in pressure-operated switch that opens to stop unit operation nearly all Thermo King units. When suction pressure reaches a predetermined minimum. Refrigerant: The medium of heat transfer in a refrigeration no. TriPac Glossary setpoint: The temperature selected on a thermostat or microprocessor controller. This is normally the desired box temperature. Short cycling: When a refrigeration unit cycles between the heat and cool modes more often than normal. Sight glass: A system component that permits visual inspection of oil or refrigerant level and condition.

If you can’t get your rig rolling, and you have tried the Thermo King North American Service Directory (available from any Thermo King dealer) to reach a dealer without success, then call the Toll Free Emergency Cold Line Number (888) 887-2202. Recover Refrigerant Recover Refrigerant At Thermo King, we recognize the need to preserve the environment and limit the potential harm to the ozone layer that can result from allowing refrigerant to escape into the atmosphere.

Thermo King Apu

We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the atmosphere. CALIFORNIA Proposition 65 Warning Diesel exhaust is a chemical known to the State of California to cause cancer. Ingersoll Rand’s Climate Solutions sector delivers energy-effi cient HVACR solutions for customers globally.

Its world class brands include Thermo King, the leader in transport temperature control and Trane, a provider of energy effi cient heating, ventilating and air conditioning systems, building and contracting services, parts support and advanced controls for commercial buildings and homes.